Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
PLoS One ; 18(2): e0278143, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2286364

RESUMEN

Real-time monitoring of serum hepatitis B virus (HBV) levels is essential for the management of patients with chronic HBV infection in clinical practice, including monitoring the resistance of anti-HBV nucleotide analog or the detection of HBV reactivation. In this context, serum HBV deoxyribonucleic acid (DNA) quantification should be rapidly measured. A rapid HBV DNA quantification assay was established on the Fully Automated Genetic Analyzer, µTASWako g1. The assay performs automated sample preparation and DNA extraction, followed by the amplification and detection of quantitative polymerase chain reaction (PCR) combined with capillary electrophoresis (qPCR-CE) on integrated microfluidic chip. This study aimed to evaluate the analytical and clinical performance of HBV DNA assay on the µTASWako g1 platform in human serum and EDTA-plasma. The HBV DNA assay has a linear quantitative range from 20 to 108 IU/mL of HBV DNA with standard deviation (SD) of ≤0.14 log10 IU/mL. The limits of detection of the assay were 4.18 for the serum and 4.35 for EDTA-plasma. The HBV assay demonstrated the equivalent performance in both human serum and EDTA-plasma matrices. The HBV genotypes A to H were detected with an accuracy of ±0.34 log10 IU/mL. In quantification range, the HBV DNA assay was correlated with Roche cobas AmpliPrep/cobas TaqMan Ver2.0 (CAP/CTM v2) (r = 0.964). The mean difference (µTASWako g1-CAP/CTM v2) of the reported HBV DNA was -0.01 log10 IU/mL. Overall, the sensitivity, accuracy, and precision of the µTASWako g1 HBV assay were comparable to the existing commercial HBV DNA assay, and the assay can be completed within 110 min. This evaluation suggests that the HBV DNA assay on the µTASWako g1 is potentially applied for alternative method of the HBV viral load test, in particular with the advantage of the HBV DNA result availability within 2 h, improving the HBV infection management.


Asunto(s)
Hepatitis B Crónica , Hepatitis B , Humanos , Virus de la Hepatitis B/genética , ADN Viral/análisis , Ácido Edético , Hepatitis B/diagnóstico , Carga Viral , Sensibilidad y Especificidad
2.
J Virol Methods ; 316: 114709, 2023 06.
Artículo en Inglés | MEDLINE | ID: covidwho-2257939

RESUMEN

High-risk human papillomavirus (hr-HPV) testing for primary cervical precancer screening offers an opportunity to improve screening in low-middle income countries (LMICs). This study aimed to compare the analytic performances of the AmpFire and MA-6000 platforms for hr-HPV DNA testing in three groups of women screened for hr-HPV types in Ghana: group 1 with 33 GeneXpert-archived ThinPrep/liquid-based samples subjected to both tests, group 2 with 50 AmpFire-archived dry brush samples subjected to MA-6000 testing, and group 3 involving 143 cotton swab samples simultaneously subjected to both tests without archiving. The overall agreement rates were 73 %, 92 %, and 84 %, for groups 1-3, respectively, and 84 % (95 % CI, 78.6-88.6) for the entire group. Neither AmpFire nor MA-6000 was more likely to test hr-HPV positive in all three groups and the combined group. Group 1 showed fair agreement without statistical significance (κ = 0.224, 95 % CI, -0.118 to 0.565), while group 3 showed significant moderate agreement (κ = 0.591, 95% CI, 0.442-0.741). Group 2 showed an almost perfect significant level of agreement (κ = 0.802; 95 % CI, 0.616-0.987). Thus, both platforms showed statistically significant moderate to near-perfect agreement for detecting hr-HPV in cervicovaginal samples, with variation according to archiving conditions and duration between sample collection and retesting. For LMICs using these platforms for COVID-19 testing, as the COVID-19 pandemic subsides, the platforms can become available for running other tests such as hr-HPV DNA testing for cervical precancer screening.


Asunto(s)
COVID-19 , Infecciones por Papillomavirus , Displasia del Cuello del Útero , Neoplasias del Cuello Uterino , Femenino , Humanos , Virus del Papiloma Humano , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/epidemiología , Prueba de COVID-19 , Pandemias , COVID-19/diagnóstico , Displasia del Cuello del Útero/diagnóstico , Reacción en Cadena de la Polimerasa , Papillomaviridae/genética , Neoplasias del Cuello Uterino/diagnóstico , Detección Precoz del Cáncer , ADN Viral/genética , ADN Viral/análisis , Sensibilidad y Especificidad
3.
Viruses ; 14(11)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: covidwho-2110272

RESUMEN

OBJECTIVES: Torquetenovirus (TTV) and Redondovirus (ReDoV) are the most prevalent viruses found in the human respiratory virome in viral metagenomics studies. A large-scale epidemiological study was performed to investigate their prevalence and loads in saliva samples according to SARS-CoV-2 status. METHODS: Saliva samples from 448 individuals (73% SARS-CoV-2 negative and 27% SARS-CoV-2 positive) aged 23-88 years were tested. SARS-CoV-2 and TTV were determined in saliva by specific qualitative and quantitative real-time PCRs, respectively. A sub-cohort of 377 subjects was additionally tested for the presence and load of ReDoV in saliva, and a different sub-cohort of 120 subjects for which paired saliva and plasma samples were available was tested for TTV and ReDoV viremia at the same timepoints as saliva. RESULTS: TTV in saliva was 72% prevalent in the entire cohort, at a mean DNA load of 4.6 log copies/mL, with no difference regardless of SARS-CoV-2 status. ReDoV was found in saliva from 61% of the entire cohort and was more prevalent in the SARS-CoV-2-negative subgroup (65% vs. 52%, respectively). In saliva, the total mean load of ReDoV was very similar to the one of TTV, with a value of 4.4 log copies/mL. The mean viral loads in subjects infected with a single virus, namely, those infected with TTV or ReDoV alone, was lower than in dually infected samples, and Tukey's multiple-comparison test showed that ReDoV single-infected samples resulted in the only true outlier (p = 0.004). Differently from TTV, ReDoV was not detected in any blood samples. CONCLUSIONS: This study establishes the prevalence and mean value of TTV and ReDoV in saliva samples and demonstrates the existence of differences between these two components of the human virome.


Asunto(s)
COVID-19 , Infecciones por Virus ADN , Torque teno virus , Humanos , Torque teno virus/genética , SARS-CoV-2/genética , Saliva , COVID-19/epidemiología , Carga Viral , ADN Viral/análisis
4.
Ocul Immunol Inflamm ; 30(5): 1260-1264, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: covidwho-1784144

RESUMEN

PURPOSE: To describe a case of herpes simplex virus 1 (HSV 1) infection following coronavirus disease 2019 (COVID-19) vaccination in an Asian Indian female. METHODS: Retrospective case report. RESULT: A 40-year-old female presented with decreased vision, pain, and photophobia of 2 weeks duration. She reported receiving the second dose of COVISHIELDTM (ChAdOx1-S [recombinant]) 1 week prior to the onset of ocular symptoms. Left eye examination revealed granulomatous anterior uveitis. Aqueous sample from the left eye tested positive for HSV1 by polymerase chain reaction(PCR) method. She was managed with oral antiviral therapy, topical steroids, and cycloplegic agent and showed significant improvement of inflammation within 1 week and resolved within 3 weeks. CONCLUSION: This report demonstrates a potential association of HSV 1 anterior uveitis with COVID-19 vaccination. A high index of suspicion of viral etiology is warranted when uveitis presents with reduced corneal sensations and pigmented keratic precipitates, following a recent history of COVID-19 vaccination.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Infecciones Virales del Ojo , Herpes Simple , Herpesvirus Humano 1 , Uveítis Anterior , Adulto , Femenino , Humanos , Antivirales/uso terapéutico , ChAdOx1 nCoV-19 , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , ADN Viral/análisis , Infecciones Virales del Ojo/diagnóstico , Infecciones Virales del Ojo/tratamiento farmacológico , Herpes Simple/diagnóstico , Herpes Simple/tratamiento farmacológico , Herpesvirus Humano 1/genética , Midriáticos/uso terapéutico , Estudios Retrospectivos , Uveítis/tratamiento farmacológico , Uveítis Anterior/inducido químicamente , Uveítis Anterior/diagnóstico , Uveítis Anterior/tratamiento farmacológico , Vacunación/efectos adversos
5.
J Nanobiotechnology ; 20(1): 41, 2022 Jan 21.
Artículo en Inglés | MEDLINE | ID: covidwho-1643157

RESUMEN

Early detection of viral pathogens by DNA-sensors in clinical samples, contaminated foods, soil or water can dramatically improve clinical outcomes and reduce the socioeconomic impact of diseases such as COVID-19. Clustered regularly interspaced short palindromic repeat (CRISPR) and its associated protein Cas12a (previously known as CRISPR-Cpf1) technology is an innovative new-generation genomic engineering tool, also known as 'genetic scissors', that has demonstrated the accuracy and has recently been effectively applied as appropriate (E-CRISPR) DNA-sensor to detect the nucleic acid of interest. The CRISPR-Cas12a from Prevotella and Francisella 1 are guided by a short CRISPR RNA (gRNA). The unique simultaneous cis- and trans- DNA cleavage after target sequence recognition at the PAM site, sticky-end (5-7 bp) employment, and ssDNA/dsDNA hybrid cleavage strategies to manipulate the attractive nature of CRISPR-Cas12a are reviewed. DNA-sensors based on the CRISPR-Cas12a technology for rapid, robust, sensitive, inexpensive, and selective detection of virus DNA without additional sample purification, amplification, fluorescent-agent- and/or quencher-labeling are relevant and becoming increasingly important in industrial and medical applications. In addition, CRISPR-Cas12a system shows great potential in the field of E-CRISPR-based bioassay research technologies. Therefore, we are highlighting insights in this research direction.


Asunto(s)
Sistemas CRISPR-Cas/fisiología , ADN Viral/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico , Animales , Técnicas Biosensibles/métodos , Técnicas Biosensibles/tendencias , COVID-19/virología , ADN Viral/análisis , Contaminantes Ambientales/análisis , Contaminantes Ambientales/aislamiento & purificación , Contaminación de Alimentos/análisis , Humanos , Tipificación Molecular/métodos , Tipificación Molecular/tendencias , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Amplificación de Ácido Nucleico/tendencias , SARS-CoV-2/genética , Virología/métodos , Virología/tendencias , Virosis/clasificación , Virosis/diagnóstico , Virosis/virología
6.
J Am Chem Soc ; 143(41): 17004-17014, 2021 10 20.
Artículo en Inglés | MEDLINE | ID: covidwho-1461966

RESUMEN

Rapid screening of infected individuals from a large population is an effective means in epidemiology, especially to contain outbreaks such as COVID-19. The gold standard assays for COVID-19 diagnostics are mainly based on the reverse transcription polymerase chain reaction, which mismatches the requirements for wide-population screening due to time-consuming nucleic acid extraction and amplification procedures. Here, we report a direct nucleic acid assay by using a graphene field-effect transistor (g-FET) with Y-shaped DNA dual probes (Y-dual probes). The assay relies on Y-dual probes modified on g-FET simultaneously targeting ORF1ab and N genes of SARS-CoV-2 nucleic acid, enabling high a recognition ratio and a limit of detection (0.03 copy µL-1) 1-2 orders of magnitude lower than existing nucleic acid assays. The assay realizes the fastest nucleic acid testing (∼1 min) and achieves direct 5-in-1 pooled testing for the first time. Owing to its rapid, ultrasensitive, easily operated features as well as capability in pooled testing, it holds great promise as a comprehensive tool for population-wide screening of COVID-19 and other epidemics.


Asunto(s)
Sondas de ADN , ADN Viral/análisis , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/virología , Grafito/química , Humanos , Límite de Detección
7.
Cancer Prev Res (Phila) ; 14(10): 919-926, 2021 10.
Artículo en Inglés | MEDLINE | ID: covidwho-1450634

RESUMEN

The World Health Organization global call to eliminate cervical cancer encourages countries to consider introducing or improving cervical cancer screening programs. Brazil's Unified Health System (SUS) is among the world's largest public health systems offering free cytology testing, follow-up colposcopy, and treatment. Yet, health care networks across the country have unequal infrastructure, human resources, equipment, and supplies resulting in uneven program performance and large disparities in cervical cancer incidence and mortality. An effective screening program needs multiple strategies feasible for each community's reality, facilitating coverage and follow-up adherence. Prioritizing those at highest risk with tests that better stratify risk will limit inefficiencies, improving program impact across different resource settings. Highly sensitive human papillomavirus (HPV)-DNA testing performs better than cytology and, with self-collection closer to homes and workplaces, improves access, even in remote regions. Molecular triage strategies like HPV genotyping can identify from the same self-collected sample, those at highest risk requiring follow-up. If proven acceptable, affordable, cost-effective, and efficient in the Brazilian context, these strategies would increase coverage while removing the need for speculum exams for routine screening and reducing follow-up visits. SUS could implement a nationwide organized program that accommodates heterogenous settings across Brazil, informing a variety of screening programs worldwide.


Asunto(s)
COVID-19/complicaciones , Citodiagnóstico/métodos , Detección Precoz del Cáncer/métodos , Papillomaviridae/aislamiento & purificación , Infecciones por Papillomavirus/complicaciones , SARS-CoV-2/aislamiento & purificación , Neoplasias del Cuello Uterino/diagnóstico , Brasil/epidemiología , ADN Viral/análisis , ADN Viral/genética , Femenino , Humanos , Infecciones por Papillomavirus/genética , Infecciones por Papillomavirus/virología , Neoplasias del Cuello Uterino/epidemiología , Neoplasias del Cuello Uterino/virología
10.
J Mater Chem B ; 9(28): 5636-5644, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: covidwho-1291040

RESUMEN

DNA polymerization is of high specificity in vivo. However, its specificity is much lower in vitro, which limits advanced applications of DNA polymerization in ultrasensitive nucleic acid detection. Herein, we report a unique mechanism of single selenium-atom modified dNTP (dNTPαSe) to enhance polymerization specificity. We have found that both dNTPαSe (approximately 660 fold) and Se-DNA (approximately 2.8 fold) have lower binding affinity to DNA polymerase than canonical ones, and the Se-DNA duplex has much lower melting-temperature (Tm) than the corresponding canonical DNA duplex. The reduced affinity and Tm can destabilize the substrate-primer-template-enzyme assembly, thereby largely slowing down the mismatch of DNA polymerization and enhancing the amplification specificity and in turn detection sensitivity. Furthermore, the Se-strategy enables us to develop the selenium enhanced specific isothermal amplification (SEA) for nucleic acid detection with high specificity and sensitivity (up to detection of single-digit copies), allowing convenient detection of clinical HPV and COVID-19 viruses in the low-copy number. Clearly, we have discovered the exciting mechanism for enhancing DNA polymerization accuracy, amplification specificity and detection sensitivity by SEA, up to two orders of magnitude higher.


Asunto(s)
ADN Viral/análisis , Papillomavirus Humano 16/aislamiento & purificación , Fosfatos/química , SARS-CoV-2/aislamiento & purificación , Selenio/química , ADN Viral/biosíntesis , Papillomavirus Humano 16/metabolismo , Humanos , Técnicas de Amplificación de Ácido Nucleico , Polimerizacion , SARS-CoV-2/metabolismo , Temperatura
11.
Biochem Biophys Res Commun ; 567: 195-200, 2021 08 27.
Artículo en Inglés | MEDLINE | ID: covidwho-1263226

RESUMEN

Recombinase polymerase amplification (RPA) is an isothermal reaction that amplifies a target DNA sequence with a recombinase, a single-stranded DNA-binding protein (SSB), and a strand-displacing DNA polymerase. In this study, we optimized the reaction conditions of RPA to detect SARS-CoV-2 DNA and RNA using a statistical method to enhance the sensitivity. In vitro synthesized SARS-CoV-2 DNA and RNA were used as targets. After evaluating the concentration of each component, the uvsY, gp32, and ATP concentrations appeared to be rate-determining factors. In particular, the balance between the binding and dissociation of uvsX and DNA primer was precisely adjusted. Under the optimized condition, 60 copies of the target DNA were specifically detected. Detection of 60 copies of RNA was also achieved. Our results prove the fabrication flexibility of RPA reagents, leading to an expansion of the use of RPA in various fields.


Asunto(s)
ADN Viral/análisis , ADN Polimerasa Dirigida por ADN/metabolismo , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas de Amplificación de Ácido Nucleico/normas , ARN Viral/análisis , Recombinasas/metabolismo , SARS-CoV-2/genética , Estadística como Asunto , Cartilla de ADN/metabolismo , Proteínas de Unión al ADN/metabolismo , Proteínas de la Membrana/metabolismo , SARS-CoV-2/aislamiento & purificación , Proteínas Virales/metabolismo
12.
Transplantation ; 105(9): 2072-2079, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1254952

RESUMEN

BACKGROUND: The impacts of COVID-19 on lung allograft function, rejection, secondary infection, and clinical outcomes in lung transplant recipients (LTRs) remain unknown. METHODS: A 1:2 matched case-control study was performed to evaluate rehospitalization, lung allograft function, and secondary infections up to 90 d after COVID-19 diagnosis (or index dates for controls). RESULTS: Twenty-four LTRs with COVID-19 (cases) and 48 controls were identified. Cases and controls had similar baseline characteristics and lung allograft function. LTRs with COVID-19 had higher incidence of secondary bacterial infection (29.2% versus 6.3%, P = 0.008), readmission (29.2% versus 10.4%, P = 0.04), and for-cause bronchoscopy (33.3% versus 12.5%, P = 0.04) compared with controls. At d 90, mortality in cases versus controls was 8.3% versus 2.1% (P = 0.21), incidence of invasive fungal infections in cases versus controls was 20.8% versus 8.3% (P = 0.13) and forced expiratory volume in 1 s (FEV1) decline ≥10% from baseline occurred in 19% of cases versus 12.2% of controls (P = 0.46). No acute cellular rejection, acute antibody-mediated rejection, or new donor-specific anti-HLA antibodies were observed among cases or controls within 90 d post index date. CONCLUSIONS: We found LTRs with COVID-19 were at risk to develop secondary infections and rehospitalization post COVID-19, compared with controls. While we did not observe post viral acute cellular rejection or antibody-mediated rejection, further studies are needed to understand if LTRs with COVID-19 who did not recover baseline lung function within 90 d have developed chronic lung allograft dysfunction stage progression.


Asunto(s)
COVID-19/epidemiología , Rechazo de Injerto/epidemiología , Enfermedades Pulmonares/cirugía , Receptores de Trasplantes , Adulto , Anciano , Aloinjertos , Comorbilidad , ADN Viral/análisis , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Enfermedades Pulmonares/epidemiología , Trasplante de Pulmón , Masculino , Persona de Mediana Edad , Pandemias , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2/genética , Estados Unidos/epidemiología
13.
Viruses ; 13(5)2021 04 29.
Artículo en Inglés | MEDLINE | ID: covidwho-1217117

RESUMEN

The availability of simple SARS-CoV-2 detection methods is crucial to contain the COVID-19 pandemic. This study examined whether a commercial LAMP assay can reliably detect SARS-CoV-2 genomes directly in respiratory samples without having to extract nucleic acids (NA) beforehand. Nasopharyngeal swabs (NPS, n = 220) were tested by real-time reverse transcription (RT)-PCR and with the LAMP assay. For RT-PCR, NA were investigated. For LAMP, NA from 26 NPS in viral transport medium (VTM) were tested. The other 194 NPS were analyzed directly without prior NA extraction (140 samples in VTM; 54 dry swab samples stirred in phosphate buffered saline). Ten NPS were tested directly by LAMP using a sous-vide cooking unit. The isothermal assay demonstrated excellent specificity (100%) but moderate sensitivity (68.8%), with a positive predictive value of 1 and a negative predictive value of 0.65 for direct testing of NPS in VTM. The use of dry swabs, even without NA extraction, improved the analytical sensitivity; up to 6% of samples showed signs of inhibition. LAMP could be performed successfully with a sous-vide cooking unit. This technique is very fast, requires little laboratory resources, and can replace rapid antigen tests or verify reactive rapid tests on-site.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ADN Viral/análisis , Técnicas de Diagnóstico Molecular/métodos , Nasofaringe/virología , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/aislamiento & purificación , Humanos , Sensibilidad y Especificidad , Manejo de Especímenes
15.
J Pediatr ; 232: 287-289.e4, 2021 05.
Artículo en Inglés | MEDLINE | ID: covidwho-1126937

RESUMEN

We conducted a multicenter clinical validity study of the Panbio coronavirus disease 2019 Antigen Rapid Test of nasopharyngeal samples in pediatric patients with coronavirus disease 2019-compatible symptoms of ≤5 days of evolution. Our study showed limited accuracy in nasopharyngeal antigen testing: overall sensitivity was 45.4%, and 99.8% of specificity, positive-predictive value was 92.5%.


Asunto(s)
Antígenos Virales/análisis , COVID-19/diagnóstico , ADN Viral/análisis , Nasofaringe/virología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/genética , Adolescente , COVID-19/virología , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Pandemias , Reproducibilidad de los Resultados , SARS-CoV-2/inmunología
16.
Anal Chem ; 93(9): 4154-4159, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: covidwho-1108879

RESUMEN

Chip-scale SARS-CoV-2 testing was demonstrated using silicon nitride (Si3N4) nanoslot fluidic waveguides to detect a tagged oligonucleotide with a coronavirus DNA sequence. The slot waveguides were fabricated using complementary metal-oxide-semiconductor (CMOS) fabrication processes, including multiscale lithography and selective reactive ion etching (RIE), forming femtoliter fluidic channels. Finite difference method (FDM) simulation was used to calculate the optical field distribution of the waveguide mode when the waveguide sensor was excited by transverse electric (TE) and transverse magnetic (TM) polarized light. For the TE polarization, a strong optical field was created in the slot region and its field intensity was 14× stronger than the evanescent sensing field from the TM polarization. The nanoscale confinement of the optical sensing field significantly enhanced the light-analyte interaction and improved the optical sensitivity. The sensitivity enhancement was experimentally demonstrated by measuring the polarization-dependent fluorescence emission from the tagged oligonucleotide. The photonic chips consisting of femtoliter Si3N4 waveguides provide a low-cost and high throughput platform for real-time virus identification, which is critical for point-of-care (PoC) diagnostic applications.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virología , ADN Viral/análisis , Nanopartículas/química , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Compuestos de Silicona/química , Humanos , Óptica y Fotónica , Sistemas de Atención de Punto , Refractometría , Semiconductores , Sensibilidad y Especificidad
17.
Talanta ; 227: 122154, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1078200

RESUMEN

Infectious diseases caused by viruses such as SARS-CoV-2 and HPV have greatly endangered human health. The nucleic acid detection is essential for the early diagnosis of diseases. Here, we propose a method called PLCR (PfAgo coupled with modified Ligase Chain Reaction for nucleic acid detection) which utilizes PfAgo to only use DNA guides longer than 14-mer to specifically cleave DNA and LCR to precisely distinguish single-base mismatch. PLCR can detect DNA or RNA without PCR at attomolar sensitivities, distinguish single base mutation between the genome of wild type SARS-CoV-2 and its mutant spike D614G, effectively distinguish the novel coronavirus from other coronaviruses and finally achieve multiplexed detection in 70 min. Additionally, LCR products can be directly used as DNA guides without additional input guides to simplify primer design. With desirable sensitivity, specificity and simplicity, the method can be extended for detecting other pathogenic microorganisms.


Asunto(s)
Proteínas Argonautas/química , ADN Viral/análisis , Reacción en Cadena de la Ligasa/métodos , Pyrococcus furiosus/enzimología , ARN Viral/análisis , Alphapapillomavirus/química , Alphapapillomavirus/aislamiento & purificación , COVID-19/diagnóstico , ADN Viral/química , Humanos , Límite de Detección , Mutación , Infecciones por Papillomavirus/diagnóstico , ARN Viral/química , SARS-CoV-2/química , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/genética
18.
J Chem Inf Model ; 60(12): 6427-6437, 2020 12 28.
Artículo en Inglés | MEDLINE | ID: covidwho-1065779

RESUMEN

CRISPR-Cas12a is a genome-editing system, recently also harnessed for nucleic acid detection, which is promising for the diagnosis of the SARS-CoV-2 coronavirus through the DETECTR technology. Here, a collective ensemble of multimicrosecond molecular dynamics characterizes the key dynamic determinants allowing nucleic acid processing in CRISPR-Cas12a. We show that DNA binding induces a switch in the conformational dynamics of Cas12a, which results in the activation of the peripheral REC2 and Nuc domains to enable cleavage of nucleic acids. The simulations reveal that large-amplitude motions of the Nuc domain could favor the conformational activation of the system toward DNA cleavages. In this process, the REC lobe plays a critical role. Accordingly, the joint dynamics of REC and Nuc shows the tendency to prime the conformational transition of the DNA target strand toward the catalytic site. Most notably, the highly coupled dynamics of the REC2 region and Nuc domain suggests that REC2 could act as a regulator of the Nuc function, similar to what was observed previously for the HNH domain in the CRISPR-associated nuclease Cas9. These mutual domain dynamics could be critical for the nonspecific binding of DNA and thereby for the underlying mechanistic functioning of the DETECTR technology. Considering that REC is a key determinant in the system's specificity, our findings provide a rational basis for future biophysical studies aimed at characterizing its function in CRISPR-Cas12a. Overall, our outcomes advance our mechanistic understanding of CRISPR-Cas12a and provide grounds for novel engineering efforts to improve genome editing and viral detection.


Asunto(s)
COVID-19/diagnóstico , ADN Viral/análisis , ADN Viral/genética , SARS-CoV-2/genética , Sistemas CRISPR-Cas , Dominio Catalítico , División del ADN , Edición Génica , Humanos , Simulación de Dinámica Molecular , Conformación de Ácido Nucleico , Transición de Fase , Especificidad por Sustrato
19.
PLoS One ; 15(10): e0241542, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-1067389

RESUMEN

Oral swabs are emerging as a non-invasive sample type for diagnosing infectious diseases including Ebola, tuberculosis (TB), and COVID-19. To assure proper sample collection, sample adequacy controls (SACs) are needed that detect substances indicative of samples collected within the oral cavity. This study evaluated two candidate SACs for this purpose. One detected representative oral microbiota (Streptococcus species DNA) and the other, human cells (human mitochondrial DNA, mtDNA). Quantitative PCR (qPCR) assays for the two target cell types were applied to buccal swabs (representing samples collected within the oral cavity) and hand swabs (representing improperly collected samples) obtained from 51 healthy U.S. volunteers. Quantification cycle (Cq) cutoffs that maximized Youden's index were established for each assay. The streptococcal target at a Cq cutoff of ≤34.9 had 99.0% sensitivity and specificity for oral swab samples, whereas human mtDNA perfectly distinguished between hand and mouth swabs with a Cq cutoff of 31.3. The human mtDNA test was then applied to buccal, tongue, and gum swabs that had previously been collected from TB patients and controls in South Africa, along with "air swabs" collected as negative controls (total N = 292 swabs from 71 subjects). Of these swabs, 287/292 (98%) exhibited the expected Cq values. In a paired analysis the three oral sites yielded indistinguishable amounts of human mtDNA, however PurFlockTM swabs collected slightly more human mtDNA than did OmniSwabsTM (p = 0.012). The results indicate that quantification of human mtDNA cannot distinguish swabs collected from different sites within the mouth. However, it can reliably distinguish oral swabs from swabs that were not used orally, which makes it a useful SAC for oral swab-based diagnosis.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Manejo de Especímenes/métodos , Adulto , COVID-19/epidemiología , COVID-19/transmisión , COVID-19/virología , ADN Mitocondrial/análisis , ADN Mitocondrial/genética , ADN Viral/análisis , ADN Viral/genética , Pruebas Diagnósticas de Rutina/métodos , Femenino , Humanos , Masculino , Boca/virología , Reacción en Cadena en Tiempo Real de la Polimerasa , Estándares de Referencia , Sensibilidad y Especificidad , Sudáfrica/epidemiología , Washingtón/epidemiología
20.
Clin Chem Lab Med ; 59(5): 987-994, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: covidwho-1024424

RESUMEN

OBJECTIVES: The qualitative results of SARS-CoV-2 specific real-time reverse transcription (RT) PCR are used for initial diagnosis and follow-up of Covid-19 patients and asymptomatic virus carriers. However, clinical decision-making and health management policies often are based additionally on cycle threshold (Ct) values (i.e., quantitative results) to guide patient care, segregation and discharge management of individuals testing positive. Therefore, an analysis of inter-protocol variability is needed to assess the comparability of the quantitative results. METHODS: Ct values reported in a SARS-CoV-2 virus genome detection external quality assessment challenge were analyzed. Three positive and two negative samples were distributed to participating test laboratories. Qualitative results (positive/negative) and quantitative results (Ct values) were assessed. RESULTS: A total of 66 laboratories participated, contributing results from 101 distinct test systems and reporting Ct values for a total of 92 different protocols. In all three positive samples, the means of the Ct values for the E-, N-, S-, RdRp-, and ORF1ab-genes varied by less than two cycles. However, 7.7% of reported results deviated by more than ±4.0 (maximum 18.0) cycles from the respective individual means. These larger deviations appear to be systematic errors. CONCLUSIONS: In an attempt to use PCR diagnostics beyond the identification of infected individuals, laboratories are frequently requested to report Ct values along with a qualitative result. This study highlights the limitations of interpreting Ct values from the various SARS-CoV genome detection protocols and suggests that standardization is necessary in the reporting of Ct values with respect to the target gene.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , ADN Viral/análisis , Genoma Viral , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/química , COVID-19/diagnóstico , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Reacciones Falso Negativas , Reacciones Falso Positivas , Humanos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA